At a Glance
An ammeter measures current in amperes and goes in series, so the current passes through it; ideally its resistance is close to zero. A voltmeter measures voltage in volts and goes in parallel across a component; ideally its resistance is very large. Both readings are linked by Ohm's law, V = I R.
- Ammeter measures
- Current I, in amperes (A)
- Voltmeter measures
- Potential difference V, in volts (V)
- Ammeter connection
- In series, current flows through it
- Voltmeter connection
- In parallel, across the component
- Ideal resistance
- Ammeter near 0 Ω; voltmeter as high as possible (often 10 MΩ)
- Circuit symbols
- A circle with the letter A; a circle with the letter V
On this page
- What Do Ammeters and Voltmeters Measure?
- Why Is an Ammeter in Series and a Voltmeter in Parallel?
- How Does a Moving-Coil Meter Work, Step by Step?
- How Do Digital Meters Measure Current and Voltage?
- What Is the Physics Behind a Meter's Range?
- Why Does Meter Resistance Matter?
- What Are the Main Types of Ammeters and Voltmeters?
- Where Are Ammeters and Voltmeters Used?
- Who Invented the Ammeter and Voltmeter?
- What Mistakes Can Damage a Meter?
- Key Facts
- Quiz
- FAQ
What Do Ammeters and Voltmeters Measure?
An ammeter measures electric current, the rate at which charge flows past a point, in amperes. A voltmeter measures voltage, the difference in electric potential between two points, in volts. The two quantities answer different questions: current tells you how much charge is moving, voltage tells you how hard it is being pushed.
Most people meet both instruments inside a single handheld multimeter, where a dial switches between modes. In school labs and on equipment panels you also find separate meters, either with a needle on a scale or with a digital display. Whatever the style, the rules for using them are the same.
Why Is an Ammeter in Series and a Voltmeter in Parallel?
An ammeter must count the charge that actually flows through a component, so the current has to pass through the meter too. You break the circuit and insert the ammeter in the gap, putting it in series. Anywhere along a single loop gives the same reading, because the current in a series circuit is the same at every point.
A voltmeter compares two points, so you touch its two leads to either side of the component without breaking anything. That places it in parallel. Because components in a parallel circuit share the same voltage, the meter reads exactly the voltage across the part it straddles.
The diagram shows both meters in place on a simple circuit: the ammeter in the main loop, the voltmeter bridged across the resistor.
Example 1 Predicting the ammeter reading
A voltmeter connected across a 150 Ω resistor reads 4.5 V. What should an ammeter in series with that resistor read?
- Given:
- voltage across the resistor:
- resistance:
- voltage across the resistor:
- Formula:
- Substitute:
- Answer:
Comparing a reading with what Ohm's law predicts is a quick way to spot a meter connected the wrong way or a faulty part.
| Feature | Ammeter | Voltmeter |
|---|---|---|
| Measures | Current (A) | Potential difference (V) |
| Connected | In series | In parallel |
| Ideal resistance | Zero | Infinite |
| Range set by | Parallel shunt resistor | Series multiplier resistor |
| Wrong connection | In parallel: short circuit, blown fuse | In series: almost no current, misleading reading |
| Circuit symbol | Circle with A | Circle with V |
| Source: Summary of standard instrument behavior · Retrieved October 2026 | ||

How Does a Moving-Coil Meter Work, Step by Step?
Classic needle meters use a moving-coil galvanometer. It works like this:
- A small coil of fine wire hangs between the poles of a permanent magnet, free to rotate on jeweled bearings or a taut band.
- Current through the coil makes it a weak electromagnet. The magnet's field exerts a torque on it, turning it.
- A hairspring resists the rotation with a torque that grows as the coil turns further.
- The coil stops where the two torques balance. Since the magnetic torque is proportional to current, the needle angle is proportional to current too, which is why the scale is evenly spaced.
- A resistor network around the coil sets the range: a tiny parallel shunt for an ammeter, or a large series multiplier for a voltmeter.
The physics of the turning coil is covered in torque on a current loop.
How Do Digital Meters Measure Current and Voltage?
A digital meter has no moving parts. At heart it is a voltmeter: an electronic circuit called an analog-to-digital converter measures a small voltage and turns it into a number. A chain of precise resistors at the input divides large voltages down to a size the converter can handle, giving the meter a high input resistance, commonly about 10 MΩ.
To measure current, the meter sends it through a small, accurately known shunt resistor and measures the tiny voltage that appears across it. Ohm's law then gives the current. That shunt is why a digital meter has separate sockets and fuses for current ranges, and why plugging the leads into the wrong socket can blow a fuse.
What Is the Physics Behind a Meter's Range?
A bare meter coil reaches full scale at a very small current, often around a milliampere, and has a modest resistance. Turning it into a useful instrument is pure Ohm's law.
For an ammeter, a low-value shunt resistor goes in parallel with the coil. Because both share one voltage, most of the current takes the easy path through the shunt and only a fixed small fraction passes through the coil. For a voltmeter, a high-value multiplier resistor goes in series with the coil, so a large voltage drives only the small full-scale current. The worked examples below size both resistors for one meter.
Both meters rest on Ohm's law, which links the voltage across a resistance to the current through it.
| Symbol | Quantity | SI unit |
|---|---|---|
| voltage across the resistor | volt (V) | |
| current | ampere (A) | |
| resistance | ohm (Ω) |
Rearranged to find another variable:
Valid for: ohmic conductors (R independent of V and I).
Example 2 Turning a sensitive meter into an ammeter
A moving-coil meter has a coil resistance of 50 Ω and reaches full scale at 1 mA (0.001 A). What shunt resistance placed in parallel with it lets the combination read up to 2 A? The shunt has the same voltage as the coil, I_g·R_g, and must carry the rest of the current, I_max minus I_g, so R = V / I gives the shunt.
- Given:
- I_g:
- R_g:
- I_max:
- I_g:
- Formula:
- Substitute:
- Answer:
The shunt is a tiny fraction of an ohm, which is exactly why a real ammeter has such a low overall resistance.
Example 3 Turning the same meter into a voltmeter
The same 50 Ω, 1 mA meter must read 10 V at full scale. What resistance must be added in series with the coil? At full scale the total resistance is 10 V divided by 1 mA, and the coil already supplies 50 Ω of it.
- Given:
- V_max:
- I_g:
- R_g:
- V_max:
- Formula:
- Substitute:
- Answer:
A large series resistor, called a multiplier, is what gives a voltmeter its high resistance.
Why Does Meter Resistance Matter?
Every real meter changes the circuit a little, an effect called loading. An ammeter adds its own resistance to the loop and slightly lowers the current. A voltmeter adds a new path in parallel and pulls some current away from the component it measures, which lowers the voltage there.
The table shows how much this matters. Two 100 kΩ resistors in series share a 12 V supply, so the true voltage across each is 6 V. A voltmeter with too low a resistance reads far below that. A typical 10 MΩ digital meter is off by only about half a percent.
The rule of thumb is simple: a voltmeter's resistance should be at least 100 times the resistance it measures across, and an ammeter's resistance should be tiny compared with the rest of the loop.
| Voltmeter resistance | Reading | Error |
|---|---|---|
| 20 kΩ | 1.714 V | 71.4% low |
| 100 kΩ | 4.000 V | 33.3% low |
| 1 MΩ | 5.714 V | 4.8% low |
| 10 MΩ (typical digital meter) | 5.970 V | 0.5% low |
| Source: Computed with the voltage-divider rule and parallel resistances; meter resistances are typical values · Retrieved October 2026 | ||

What Are the Main Types of Ammeters and Voltmeters?
- Moving-coil (analog) meters use a galvanometer and a needle. They show trends well and need no battery for basic readings.
- Digital multimeters combine voltage, current and resistance ranges in one handheld unit and are the everyday tool of technicians and students.
- Clamp meters measure current without breaking the circuit. Their jaws close around a single wire and sense its magnetic field, using the same idea as a transformer for AC.
- Panel meters are built into power supplies, chargers and control panels to show voltage or current continuously.
- Oscilloscopes act as fast voltmeters that draw voltage against time, useful for changing signals.

Where Are Ammeters and Voltmeters Used?
Electricians use voltmeters to confirm that a circuit is dead before touching it and to check outlets and breakers. Car mechanics measure battery voltage and the small current a parked car draws, to track down a drain that flattens the battery overnight.
In the classroom, the two meters together let you plot current against voltage and find resistance from the slope, as in our Ohm's law graph experiment. Solar installers watch panel voltage and current to judge output, and electronics designers measure the current a gadget draws to predict its battery life.
Who Invented the Ammeter and Voltmeter?
The story starts in 1820, when Hans Christian Ørsted noticed that a current-carrying wire deflects a compass needle. Within months, experimenters wrapped wire in many turns around a needle to multiply the effect, creating the first galvanometers, named in honor of Luigi Galvani. André-Marie Ampère argued that this deflection could be used to measure current, and the unit of current now carries his name.
In the early 1880s the moving-coil design, with the coil turning inside a fixed magnet, made meters rugged and accurate enough for practical work. Digital meters became common in the late twentieth century as integrated circuits made them cheap.
What Mistakes Can Damage a Meter?
The most common mistake is connecting an ammeter in parallel, straight across a battery or an outlet. With almost no resistance, it creates a short circuit; a huge current flows and the meter's fuse blows, or worse. Always switch the leads back to the voltage socket after measuring current.
Putting a voltmeter in series is harmless but useless: its high resistance chokes the current, and it simply reads roughly the supply voltage. On mains circuits, only use meters rated for that voltage category and keep fingers behind the probe guards.
Myth: An ammeter uses up some of the current, so it should go after the bulb.
Physics: Current is the same everywhere in a series loop. The ammeter reads the same value before or after the bulb.
Myth: A voltmeter measures the voltage at one point.
Physics: Voltage is always a difference between two points, which is why a voltmeter has two leads placed on either side of a component.
Myth: Any meter can be connected any way as long as the range is high enough.
Physics: An ammeter in parallel creates a near short circuit regardless of range. Connection, not just range, decides whether a reading is safe and correct.
Key Facts
- An ammeter measures current and is always connected in series with the component.
- A voltmeter measures potential difference and is always connected in parallel across the component.
- An ideal ammeter has zero resistance and an ideal voltmeter has infinite resistance.
- A moving-coil meter becomes an ammeter with a small parallel shunt and a voltmeter with a large series multiplier.
- Digital meters measure current by reading the small voltage across a known shunt resistor.
- A voltmeter with too low a resistance reads below the true voltage, an effect called loading.
- Connecting an ammeter directly across a supply creates a short circuit and usually blows the meter's fuse.
Quick Quiz: How Well Do You Know Ammeters and Voltmeters?
6 questions. Tap an answer to check it.
How is an ammeter connected in a circuit?
The current must pass through the ammeter, so it goes in series.
What is the ideal resistance of a voltmeter?
A huge resistance means the voltmeter draws almost no current.
To turn a galvanometer into an ammeter, you add:
A low-value parallel shunt carries most of the current around the coil.
A voltmeter reads 6 V across a 30 Ω resistor. What does an ammeter in series read?
I = V / R = 6 V / 30 Ω = 0.2 A.
What usually happens if an ammeter is connected directly across a battery?
Its near-zero resistance lets a very large current flow.
Why does a low-resistance voltmeter read too low?
Its parallel path lowers the effective resistance and the voltage across the component.
Frequently Asked Questions
What is the difference between an ammeter and a voltmeter?
An ammeter measures current, the flow of charge, in amperes, and it is placed in series so the current passes through it. A voltmeter measures voltage, the potential difference between two points, in volts, and it is placed in parallel across a component. An ammeter has very low resistance, while a voltmeter has very high resistance.
Why is an ammeter connected in series?
An ammeter has to measure the current that actually flows through a component, so that same current must flow through the meter. Placing it in series forces all the charge to pass through it. Because its resistance is tiny, it barely changes the current it measures. In parallel, it would offer a shortcut and draw a dangerously large current.
Why is a voltmeter connected in parallel?
Voltage is the difference in potential between two points, and components in parallel always share the same voltage. Connecting the voltmeter's leads to either side of a component puts it in parallel, so it sees exactly that voltage. Its very high resistance means it draws almost no current, leaving the circuit nearly undisturbed.
What happens if you connect an ammeter in parallel?
The ammeter's very low resistance gives the current an easy shortcut around the component. A large current rushes through the meter, which is effectively a short circuit. In a digital multimeter the internal fuse usually blows; with a powerful source the meter or wiring can be damaged, and sparks or heat are possible. Always check the lead sockets first.
What happens if you connect a voltmeter in series?
Its huge resistance blocks almost all of the current, so the lamp or device in the circuit stops working. The voltmeter then reads close to the full supply voltage, because nearly all of the voltage drops across the meter. Nothing is damaged in most cases, but the reading tells you nothing useful about the component.
What is the resistance of an ideal ammeter and voltmeter?
An ideal ammeter has zero resistance, so it adds nothing to the loop and leaves the current unchanged. An ideal voltmeter has infinite resistance, so it draws no current from the circuit. Real meters only approach these ideals; a typical digital multimeter has about 10 megaohms on its voltage ranges and a fraction of an ohm on current ranges.
Can a multimeter be used as both an ammeter and a voltmeter?
Yes. A multimeter switches internal circuits to act as a voltmeter, an ammeter or an ohmmeter. For voltage you use the volt socket and connect in parallel. For current you move the red lead to the amp socket and connect in series. Forgetting to move the lead back is the most common way to blow a multimeter fuse.
What is a galvanometer?
A galvanometer is a very sensitive current detector, usually a small coil that turns in a magnetic field and moves a needle. On its own it reaches full scale at a tiny current. Adding a small parallel shunt turns it into an ammeter, and adding a large series resistor turns it into a voltmeter. Classic analog meters are all built this way.
Sources
Constants come from NIST CODATA 2022 (public domain) and unit definitions from the BIPM SI Brochure (CC BY 4.0). Text, diagrams and illustrations are original work by Physics Tribune.