At a Glance
A mass spectrometer ionizes a sample, accelerates the ions, filters them to one speed and sends them through a magnetic field, where each follows a circle of radius r = m v / (q B). Heavier ions trace bigger circles, so measuring where they land gives their mass-to-charge ratio and the makeup of the sample.
- Measures
- Mass-to-charge ratio (m/q) of ions
- Key formula
- r = mv / (qB)
- Main stages
- Ionize, accelerate, select speed, deflect, detect
- Mass unit used
- Atomic mass unit u (dalton), 1.660 539 068 92 × 10⁻²⁷ kg
- First built
- Around 1919 (Francis Aston's mass spectrograph)
- Used for
- Isotopes, drug tests, dating, chemical analysis
On this page
- What Is a Mass Spectrometer?
- How Does a Mass Spectrometer Work, Step by Step?
- What Physics Makes a Mass Spectrometer Work?
- How Does a Mass Spectrometer Separate Isotopes?
- What Are the Main Types of Mass Spectrometers?
- What Is a Mass Spectrometer Used For?
- Who Invented the Mass Spectrometer?
- Common Misconceptions
- Key Facts
- Quiz
- FAQ
What Is a Mass Spectrometer?
A mass spectrometer is a sorting machine for atoms and molecules. It cannot weigh a single atom on a scale, so instead it gives each particle an electric charge, launches it, and watches how hard it is to steer. A heavy ion resists turning; a light one swerves easily.
The output is a mass spectrum: a chart of how many ions arrived at each mass-to-charge ratio. Each peak stands for one kind of ion, and the height of the peak shows how common it is. From that pattern a chemist can identify a compound, measure the mix of isotopes in an element, or detect a trace substance at parts per billion.
The classic design described here uses a magnetic field to do the sorting. It is a direct application of the magnetic force on a moving charge.
How Does a Mass Spectrometer Work, Step by Step?
- Vaporize. The sample is turned into a gas inside a vacuum chamber, so ions can travel without hitting air molecules.
- Ionize. A beam of electrons knocks an electron off each atom or molecule, leaving a positive ion. Most carry a charge of +1e.
- Accelerate. A voltage between two plates pulls the ions through a slit. Each ion gains kinetic energy qV, as in the diagram of the accelerating plates below.
- Select a speed. A velocity selector applies crossed electric and magnetic fields. Only ions with speed v = E/B feel balanced forces and go straight through.
- Deflect. The ions enter a uniform magnetic field at right angles. The magnetic force acts as a centripetal force and bends each ion onto a semicircle.
- Detect. A detector or photographic plate records where ions land and how many arrive. Distance from the entry slit gives the radius, and the radius gives the mass.
Modern instruments often skip the photographic plate and sweep the field strength instead, letting ions of each mass hit one fixed detector in turn.
Example 1 Setting the velocity selector
In a velocity selector, crossed fields of E = 3.0 × 10⁴ V/m and B = 0.15 T let only ions of one speed pass straight through. What speed is that?
- Given:
- electric field in the selector:
- magnetic field:
- electric field in the selector:
- Formula:
- Substitute:
- Answer:
(720,000 km/h, 447,400 mph)
Faster ions are bent one way and slower ions the other, so only this speed reaches the deflection stage.

What Physics Makes a Mass Spectrometer Work?
Inside the deflection region the magnetic force
When every ion has the same speed and the same charge, radius is directly proportional to mass. Double the mass and the circle doubles in size. That straight-line link is what makes the device a scale.
If you skip the velocity selector and just accelerate ions from rest through a voltage V, energy conservation gives
Here is the formula for the radius of an ion's path, with each symbol and its SI unit, plus the forms solved for speed, field and mass.
| Symbol | Quantity | SI unit |
|---|---|---|
| radius of the circular path | meter (m) | |
| mass of the particle | kilogram (kg) | |
| speed (perpendicular to B) | meter per second (m/s) | |
| charge | coulomb (C) | |
| magnetic field | tesla (T) |
Rearranged to find another variable:
Valid for: velocity perpendicular to a uniform B field.
Example 2 Radius of a carbon-12 ion
A singly charged carbon-12 ion (mass 1.9926 × 10⁻²⁶ kg, charge 1.602 × 10⁻¹⁹ C) starts from rest and is accelerated through 2,000 V. It then enters a 0.25 T magnetic field at right angles. What is the radius of its path?
- Given:
- mass of the particle:
- charge:
- magnetic field:
- accelerating voltage:
- mass of the particle:
- Formula:
- Substitute:
- Answer:
The accelerating voltage sets the speed through qV = ½mv², which is folded into this one-step form of r = mv/(qB).
How Does a Mass Spectrometer Separate Isotopes?
Isotopes of an element have the same chemistry but slightly different masses, because their nuclei hold different numbers of neutrons. A mass spectrometer does not care about chemistry. It only sees mass and charge, so isotopes that no chemical test can tell apart land a few millimeters from each other.
The table shows singly charged ions accelerated from rest through 2,000 V in a 0.25 T field. Carbon-12 and carbon-13 differ by only one neutron, yet their landing points are about 7 mm apart, an easy gap for a detector to resolve. The circular-motion diagram shows the carbon-12 case, with its speed and the magnetic force that holds it on the curve.
Example 3 Identifying an unknown ion
Singly charged ions leave a velocity selector at 2.0 × 10⁵ m/s and enter a 0.30 T field, where they follow a circle of radius 0.1106 m. What is the mass of each ion?
- Given:
- charge:
- magnetic field:
- radius of the circular path:
- speed (perpendicular to B):
- charge:
- Formula:
- Substitute:
- Answer:
Dividing by the atomic mass unit gives about 16 u, which points to oxygen-16.
| Ion | Mass (approx., u) | Speed (m/s) | Path radius (cm) | Landing distance from slit (cm) |
|---|---|---|---|---|
| Carbon-12 | 12 | 179,300 | 8.92 | 17.84 |
| Carbon-13 | 13 | 172,300 | 9.29 | 18.57 |
| Carbon-14 | 14 | 166,000 | 9.64 | 19.27 |
| Neon-20 | 20 | 138,900 | 11.52 | 23.04 |
| Neon-22 | 22 | 132,400 | 12.08 | 24.16 |
| Chlorine-35 | 35 | 105,000 | 15.24 | 30.47 |
| Chlorine-37 | 37 | 102,100 | 15.67 | 31.33 |
| Source: Computed with qV = ½mv² and r = mv/(qB); masses taken as mass number × atomic mass constant, q = elementary charge (NIST CODATA 2022) · Retrieved October 2026 | ||||

What Are the Main Types of Mass Spectrometers?
- Magnetic sector: the design on this page. A curved magnet bends the beam, and the bend depends on mass. It is still prized for very precise isotope ratios.
- Time-of-flight: every ion gets the same kinetic energy and races down a long field-free tube. Light ions arrive first, and the arrival time gives the mass.
- Quadrupole: four parallel rods carry rapidly alternating voltages. For each setting only one mass range follows a stable path through the rods, so sweeping the voltages scans the spectrum.
- Ion trap: electric fields hold ions in a small region, then release them mass by mass, or measure how fast each mass oscillates.
- Tandem instruments: two analyzers in a row. The first picks one ion, a collision cell breaks it apart, and the second weighs the fragments to reveal the molecule's structure.
What Is a Mass Spectrometer Used For?
Mass spectrometers sit in hospitals, crime labs, oil refineries and space probes. A short list of jobs they do every day:
- Medicine: screening newborn blood spots for inherited metabolic disorders and measuring drug levels in patients.
- Sports and forensics: confirming banned substances in urine samples and identifying unknown powders.
- Dating: accelerator mass spectrometry counts individual carbon-14 atoms, so radiocarbon dates can be made from samples as small as a seed.
- Climate and geology: oxygen isotope ratios in ice cores and shells record past temperatures.
- Space science: instruments on planetary probes have measured the gases in other planets' atmospheres.
- Industry: checking the purity of chemicals and finding leaks in vacuum systems using helium as a tracer.

Who Invented the Mass Spectrometer?
The idea grew out of the study of positive rays in gas discharge tubes. Around 1913, J. J. Thomson bent these rays with electric and magnetic fields and found two separate traces for neon, an early hint that a stable element could have isotopes of different mass. His work on cathode rays is retold in our cathode ray experiment page.
His assistant Francis Aston built a much sharper instrument, the mass spectrograph, around 1919. With it he showed that many ordinary elements are mixtures of isotopes, and he received the 1922 Nobel Prize in Chemistry. Over the following decades the instrument shrank from room-sized magnets to benchtop boxes and handheld units.
Common Misconceptions
Myth: A mass spectrometer measures mass directly.
Physics: It measures the mass-to-charge ratio. An ion with twice the mass and twice the charge lands in the same spot as the original, which analysts must account for.
Myth: The magnetic field speeds the ions up.
Physics: The magnetic force is perpendicular to the motion, so it only bends the path. The ions get their speed from the electric accelerating voltage.
Myth: Heavier ions are bent more by the magnet.
Physics: Heavier ions have more momentum and bend less, so they follow larger circles and land farther from the entry slit.
Key Facts
- A mass spectrometer sorts ions by their mass-to-charge ratio and records how many of each arrive.
- In a magnetic field an ion follows a circle of radius r = mv/(qB).
- At equal speed and charge, the path radius is directly proportional to mass.
- A velocity selector passes only ions with speed v = E/B.
- The whole instrument runs in a vacuum so ions do not collide with air.
- Francis Aston's mass spectrograph of about 1919 proved that many elements are mixtures of isotopes.
- Modern types include magnetic sector, time-of-flight, quadrupole and ion trap analyzers.
Quick Quiz: How Well Do You Know Mass Spectrometer?
5 questions. Tap an answer to check it.
What does a mass spectrometer actually measure for each ion?
The bending depends on m/q, so ions are sorted by that ratio.
Two ions have the same speed and charge, but one has twice the mass. How do their path radii compare?
r = mv/(qB), so radius is proportional to mass at fixed v, q and B.
Why must the inside of a mass spectrometer be a vacuum?
Collisions would knock ions off their paths and blur the spectrum.
In a velocity selector with E = 4.0 × 10⁴ V/m and B = 0.20 T, which ions pass straight through?
The forces balance when v = E/B, which is 2.0 × 10⁵ m/s here.
Which scientist won the 1922 Nobel Prize in Chemistry for work with the mass spectrograph?
Aston used his instrument to show that many elements are mixtures of isotopes.
Frequently Asked Questions
What is a mass spectrometer in simple terms?
It is a machine that weighs atoms and molecules by giving them an electric charge and seeing how much a magnetic or electric field can steer them. Light particles turn easily and heavy ones resist. By recording where the particles land, or when they arrive, the machine builds a chart of all the masses present in a sample.
What are the five stages of a mass spectrometer?
The usual list is ionization, acceleration, deflection, detection and data analysis, often with a velocity selection step between acceleration and deflection. The sample is first vaporized in a vacuum, then ionized by an electron beam, accelerated by a voltage, bent by a magnetic field according to its mass-to-charge ratio, and finally counted by a detector that sends signals to a computer.
Why do lighter ions bend more in a mass spectrometer?
The magnetic force on an ion depends on its charge, speed and the field, not on its mass. A lighter ion has less momentum, so the same sideways force changes its direction more quickly. In the formula r = mv/(qB), a smaller mass means a smaller radius, so the light ion's path curves more tightly.
What does a mass spectrum show?
A mass spectrum is a graph with mass-to-charge ratio along the horizontal axis and the number of ions detected on the vertical axis. Each peak marks one kind of ion. For an element, the peaks show its isotopes and their relative abundance. For a molecule, the tallest peaks and the pattern of fragments act like a fingerprint for identification.
How is a mass spectrometer used to find isotopes?
All isotopes of an element have the same charge after ionization but slightly different masses. When they pass through the magnetic field at the same speed, the heavier isotopes follow larger circles and land a little farther away. The positions identify the isotopes, and the number of ions at each position gives their percentage in the sample.
Why are the ions positive in most mass spectrometers?
The common ionization method fires fast electrons at the sample, which knock an electron out of each atom or molecule. Losing an electron leaves a positive ion. Some instruments are set up for negative ions instead, simply by reversing the voltages, but positive ions are the standard choice for most everyday analysis work.
Who invented the mass spectrometer?
J. J. Thomson laid the groundwork around 1913 by bending positive rays with electric and magnetic fields and spotting two forms of neon. His colleague Francis Aston built the first true mass spectrograph around 1919 and used it to find isotopes in many elements, work that earned him the 1922 Nobel Prize in Chemistry.
What is a mass spectrometer used for in everyday life?
Hospitals use it to screen newborns for metabolic disorders and to check drug levels. Forensic and sports labs confirm drugs and poisons. Archaeologists date ancient material by counting carbon-14 atoms. Food and water labs test for pesticides and pollutants, and engineers use helium mass spectrometers to find tiny leaks in sealed equipment.